DataFlash\r_pfdl.c(107):W0520188:Enumerated type mixed with another type
DataFlash\r_pfdl.c(137):W0520188:Enumerated type mixed with another type
DataFlash\r_pfdl.c(162):W0520188:Enumerated type mixed with another type
DataFlash\r_pfdl.c(166):W0520940:Missing return statement at end of non-void function "WriteDataflash"
DataFlash\r_pfdl.c(248):W0520188:Enumerated type mixed with another type
DataFlash\r_pfdl.c(254):W0520188:Enumerated type mixed with another type
DataFlash\r_pfdl.c(262):W0520188:Enumerated type mixed with another type
DataFlash\r_pfdl.c(292):W0520513:A value of type "uint32_t __near" cannot be assigned to an entity of type "volatile uint8_t *"
rscan_driver\r_rl78_can_drv.c(846):W0523076:Function declarations should have prototype
r_cg_timer_user.c(142):W0520167:Argument of type "uint16_t __near *" is incompatible with parameter of type "unsigned int *__near"
diagnose\Dcm_App.c(296):W0520549:Variable "DcmResetDelay" is used before its value is set
diagnose\Dcm_App.c(320):W0520177:Variable "ResetDelayCnt" was declared but never referenced
diagnose\Dcm_App.c(470):W0520177:Variable "ResetDelayCnt" was declared but never referenced
diagnose\Dcm_App.c(899):W0520549:Variable "LeDcm_u_Result" is used before its value is set
diagnose\Dcm_App.c(966):W0520549:Variable "LeDcm_u_Result" is used before its value is set
diagnose\Dcm_App.c(917):W0520177:Variable "LaDcm_u_TempBuffer" was declared but never referenced
diagnose\Dcm_App.c(1281):W0520940:Missing return statement at end of non-void function "MngDcm_RoutineF001Start"
diagnose\Dcm_App.c(1285):W0520940:Missing return statement at end of non-void function "MngDcm_RoutineF001Stop"
diagnose\Dcm_App.c(1289):W0520940:Missing return statement at end of non-void function "MngDcm_RoutineF001Result"
diagnose\Dcm_App.c(1559):W0520177:Variable "temp" was declared but never referenced
diagnose\Dcm_App.c(1906):W0520549:Variable "LeDcm_u_FinallyResult" is used before its value is set
diagnose\Dcm_App.c(1840):W0520177:Variable "LeDcm_u_dataFomatldentifier" was declared but never referenced
diagnose\Dcm_App.c(1841):W0520177:Variable "LeDcm_u_addressAndLengthFomatldentifier" was declared but never referenced
diagnose\Dcm_App.c(1842):W0520177:Variable "LeDcm_w_Address" was declared but never referenced
diagnose\Dcm_App.c(1843):W0520177:Variable "LeDcm_w_DataLength" was declared but never referenced
diagnose\Dcm_App.c(1844):W0520177:Variable "LeDcm_u_SidIndex" was declared but never referenced
diagnose\Dcm_App.c(1845):W0520177:Variable "LeDcm_u_SecurityAccessCheckResult" was declared but never referenced
diagnose\Dcm_App.c(1846):W0520177:Variable "LaDcm_u_TempBuffer" was declared but never referenced
diagnose\Dcm_App.c(2010):W0520549:Variable "LeDcm_u_FinallyResult" is used before its value is set
diagnose\Dcm_App.c(1926):W0520177:Variable "LeDcm_w_SingleTransmitDataCount" was declared but never referenced
diagnose\Dcm_App.c(1927):W0520177:Variable "LeDcm_u_BlockSequenceCount" was declared but never referenced
diagnose\Dcm_App.c(1928):W0520177:Variable "LeDcm_u_BlockExpect" was declared but never referenced
diagnose\Dcm_App.c(1929):W0520177:Variable "LaDcm_u_TempBuffer" was declared but never referenced
diagnose\Dcm_App.c(60):W0520177:Variable "CeDcm_w_SecurityAccessFBLMask" was declared but never referenced
diagnose\Dcm_App.c(63):W0520177:Variable "SeDcm_w_DownLoadDataLength" was declared but never referenced
diagnose\Dcm_App.c(64):W0520177:Variable "SeDcm_w_TransmitDataCount" was declared but never referenced
diagnose\Dcm_App.c(65):W0520177:Variable "SeDcm_u_BlockSequenceCountSts" was declared but never referenced
diagnose\Dcm_App.c(66):W0520177:Variable "CaDcm_w_SingleAllowDateLength" was declared but never referenced
diagnose\Dcm_App.c(71):W0520177:Variable "SeDcm_u_RidF001Sts" was declared but never referenced
diagnose\Dcm_Cfg.c(83):W0520144:A value of type "uint8 (__far *)(void)" cannot be used to initialize an entity of type "SubDealfunc"
diagnose\Dcm_Cfg.c(84):W0520144:A value of type "uint8 (__far *)(void)" cannot be used to initialize an entity of type "SubDealfunc"
diagnose\Dcm_Cfg.c(87):W0520144:A value of type "uint8 (__far *)(void)" cannot be used to initialize an entity of type "SubDealfunc"
diagnose\Dcm_Cfg.c(1157):W0520940:Missing return statement at end of non-void function "MngDcm_ReadMemoryDataService"
diagnose\Dcm_Cfg.c(1179):W0520167:Argument of type "const TsDcm_h_WithParaSubCheckType __near *" is incompatible with parameter of type "const TsDcm_h_SubCheckType __far *__near"
diagnose\Dcm_Cfg.c(1199):W0520167:Argument of type "const TsDcm_h_WithParaSubCheckType __near *" is incompatible with parameter of type "const TsDcm_h_SubCheckType __far *__near"
diagnose\Dcm_Cfg.c(1240):W0520167:Argument of type "const TsDcm_h_WithParaSubCheckType __near *" is incompatible with parameter of type "const TsDcm_h_SubCheckType __far *__near"
diagnose\Dcm_Cfg.c(1259):W0520167:Argument of type "const TsDcm_h_WithParaSubCheckType __near *" is incompatible with parameter of type "const TsDcm_h_SubCheckType __far *__near"
diagnose\Dcm_Cfg.c(1294):W0520177:Variable "i" was declared but never referenced
diagnose\Dcm_Cfg.c(1304):W0520177:Variable "LeDcm_u_CollectDataPost" was declared but never referenced
diagnose\Dcm_Cfg.c(1597):W0520177:Variable "LeDcm_u_DLCheckResult" was declared but never referenced
diagnose\Dcm_Cfg.c(1603):W0520177:Variable "LeDcm_u_CollectDataPost" was declared but never referenced
diagnose\Dcm_Cfg.c(509):W0520177:Function "MngDcm_2AReadDidCheckDL" was declared but never referenced
diagnose\Dcm_Cfg.c(551):W0520177:Function "MngDcm_IoDidCheckDL" was declared but never referenced
diagnose\Dcm_Key.c(76):W0520177:Variable "key_test" was declared but never referenced
diagnose\Dcm_Key.c(108):W0520940:Missing return statement at end of non-void function "GENERIC_ALGORITHM"
diagnose\CanIf\CanIf.c(299):W0520550:Variable "temp" was set but never used
diagnose\CanIf\CanIf.c(389):W0520188:Enumerated type mixed with another type
diagnose\CanIf\CanIf.c(20):W0520550:Variable "TsCanIf_h_TxQueue" was set but never used
diagnose\CanIf\CanIf_Cfg.c(33):W0520009:Nested comment is not allowed
diagnose\CanIf\CanIf_Cfg.c(43):W0520009:Nested comment is not allowed
diagnose\DTC\DCM_DTC.c(111):W0520167:Argument of type "uint32 __near *" is incompatible with parameter of type "unsigned char *__near"
diagnose\DTC\DCM_DTC.c(175):W0520167:Argument of type "uint8 __near (*)[2]" is incompatible with parameter of type "unsigned char *__near"
diagnose\DTC\DCM_DTC.c(166):W0520177:Variable "DtcSnapshotRecord" was declared but never referenced
diagnose\DTC\DCM_DTC.c(780):W0520167:Argument of type "uint8 __near (*)[28]" is incompatible with parameter of type "unsigned char *__near"
diagnose\DTC\DCM_DTC.c(97):W0520177:Function "ChkDiagVolt" was declared but never referenced
diagnose\DTC\DCM_DTC.c(107):W0520177:Function "GetLastSnapshotRecordNum" was declared but never referenced
diagnose\Dcm.c(69):W0520550:Variable "LeDcm_u_FinallyResult" was set but never used
diagnose\CanTp\CanTp.c(192):W0520069:Integer conversion resulted in truncation
diagnose\CanTp\CanTp.c(786):W0520188:Enumerated type mixed with another type
user\appTask.c(144):W0520550:Variable "temp_N_state" was set but never used
user\appTask.c(146):W0520177:Variable "db_pos" was declared but never referenced
user\appTask.c(50):W0520177:Variable "err_counter" was declared but never referenced