r_main.c(116):W0523077:Called function should have prototype
r_main.c(162):W0523076:Function declarations should have prototype
r_cg_timer_user.c(142):W0520167:Argument of type "uint16_t __near *" is incompatible with parameter of type "unsigned int *__near"
diagnose\Dcm_App.c(296):W0520549:Variable "DcmResetDelay" is used before its value is set
diagnose\Dcm_App.c(320):W0520177:Variable "ResetDelayCnt" was declared but never referenced
diagnose\Dcm_App.c(470):W0520177:Variable "ResetDelayCnt" was declared but never referenced
diagnose\Dcm_App.c(912):W0520549:Variable "LeDcm_u_Result" is used before its value is set
diagnose\Dcm_App.c(979):W0520549:Variable "LeDcm_u_Result" is used before its value is set
diagnose\Dcm_App.c(930):W0520177:Variable "LaDcm_u_TempBuffer" was declared but never referenced
diagnose\Dcm_App.c(1294):W0520940:Missing return statement at end of non-void function "MngDcm_RoutineF001Start"
diagnose\Dcm_App.c(1298):W0520940:Missing return statement at end of non-void function "MngDcm_RoutineF001Stop"
diagnose\Dcm_App.c(1302):W0520940:Missing return statement at end of non-void function "MngDcm_RoutineF001Result"
diagnose\Dcm_App.c(1572):W0520177:Variable "temp" was declared but never referenced
diagnose\Dcm_App.c(1919):W0520549:Variable "LeDcm_u_FinallyResult" is used before its value is set
diagnose\Dcm_App.c(1853):W0520177:Variable "LeDcm_u_dataFomatldentifier" was declared but never referenced
diagnose\Dcm_App.c(1854):W0520177:Variable "LeDcm_u_addressAndLengthFomatldentifier" was declared but never referenced
diagnose\Dcm_App.c(1855):W0520177:Variable "LeDcm_w_Address" was declared but never referenced
diagnose\Dcm_App.c(1856):W0520177:Variable "LeDcm_w_DataLength" was declared but never referenced
diagnose\Dcm_App.c(1857):W0520177:Variable "LeDcm_u_SidIndex" was declared but never referenced
diagnose\Dcm_App.c(1858):W0520177:Variable "LeDcm_u_SecurityAccessCheckResult" was declared but never referenced
diagnose\Dcm_App.c(1859):W0520177:Variable "LaDcm_u_TempBuffer" was declared but never referenced
diagnose\Dcm_App.c(2023):W0520549:Variable "LeDcm_u_FinallyResult" is used before its value is set
diagnose\Dcm_App.c(1939):W0520177:Variable "LeDcm_w_SingleTransmitDataCount" was declared but never referenced
diagnose\Dcm_App.c(1940):W0520177:Variable "LeDcm_u_BlockSequenceCount" was declared but never referenced
diagnose\Dcm_App.c(1941):W0520177:Variable "LeDcm_u_BlockExpect" was declared but never referenced
diagnose\Dcm_App.c(1942):W0520177:Variable "LaDcm_u_TempBuffer" was declared but never referenced
diagnose\Dcm_App.c(60):W0520177:Variable "CeDcm_w_SecurityAccessFBLMask" was declared but never referenced
diagnose\Dcm_App.c(63):W0520177:Variable "SeDcm_w_DownLoadDataLength" was declared but never referenced
diagnose\Dcm_App.c(64):W0520177:Variable "SeDcm_w_TransmitDataCount" was declared but never referenced
diagnose\Dcm_App.c(65):W0520177:Variable "SeDcm_u_BlockSequenceCountSts" was declared but never referenced
diagnose\Dcm_App.c(66):W0520177:Variable "CaDcm_w_SingleAllowDateLength" was declared but never referenced
diagnose\Dcm_App.c(71):W0520177:Variable "SeDcm_u_RidF001Sts" was declared but never referenced
diagnose\Dcm_Cfg.c(83):W0520144:A value of type "uint8 (__far *)(void)" cannot be used to initialize an entity of type "SubDealfunc"
diagnose\Dcm_Cfg.c(84):W0520144:A value of type "uint8 (__far *)(void)" cannot be used to initialize an entity of type "SubDealfunc"
diagnose\Dcm_Cfg.c(87):W0520144:A value of type "uint8 (__far *)(void)" cannot be used to initialize an entity of type "SubDealfunc"
diagnose\Dcm_Cfg.c(1166):W0520940:Missing return statement at end of non-void function "MngDcm_ReadMemoryDataService"
diagnose\Dcm_Cfg.c(1188):W0520167:Argument of type "const TsDcm_h_WithParaSubCheckType __near *" is incompatible with parameter of type "const TsDcm_h_SubCheckType __far *__near"
diagnose\Dcm_Cfg.c(1208):W0520167:Argument of type "const TsDcm_h_WithParaSubCheckType __near *" is incompatible with parameter of type "const TsDcm_h_SubCheckType __far *__near"
diagnose\Dcm_Cfg.c(1249):W0520167:Argument of type "const TsDcm_h_WithParaSubCheckType __near *" is incompatible with parameter of type "const TsDcm_h_SubCheckType __far *__near"
diagnose\Dcm_Cfg.c(1268):W0520167:Argument of type "const TsDcm_h_WithParaSubCheckType __near *" is incompatible with parameter of type "const TsDcm_h_SubCheckType __far *__near"
diagnose\Dcm_Cfg.c(1303):W0520177:Variable "i" was declared but never referenced
diagnose\Dcm_Cfg.c(1313):W0520177:Variable "LeDcm_u_CollectDataPost" was declared but never referenced
diagnose\Dcm_Cfg.c(1606):W0520177:Variable "LeDcm_u_DLCheckResult" was declared but never referenced
diagnose\Dcm_Cfg.c(1612):W0520177:Variable "LeDcm_u_CollectDataPost" was declared but never referenced
diagnose\Dcm_Cfg.c(518):W0520177:Function "MngDcm_2AReadDidCheckDL" was declared but never referenced
diagnose\Dcm_Cfg.c(560):W0520177:Function "MngDcm_IoDidCheckDL" was declared but never referenced
diagnose\Dcm_DID_Cfg.c(173):W0520144:A value of type "long" cannot be used to initialize an entity of type "uint8 __far *__near"
diagnose\Dcm_DID_Cfg.c(173):W0520152:Conversion of nonzero integer to pointer
diagnose\Dcm_DID_Cfg.c(338):W0520174:Expression has no effect
diagnose\Dcm_DID_Cfg.c(348):W0520144:A value of type "long" cannot be used to initialize an entity of type "uint8 __far *__near"
diagnose\Dcm_DID_Cfg.c(348):W0520152:Conversion of nonzero integer to pointer
diagnose\Dcm_DID_Cfg.c(370):W0520144:A value of type "long" cannot be used to initialize an entity of type "uint8 __far *__near"
diagnose\Dcm_DID_Cfg.c(370):W0520152:Conversion of nonzero integer to pointer
diagnose\Dcm_DID_Cfg.c(402):W0520174:Expression has no effect